CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to connector P115 socket 17.
(3) Connect negative (-) probe of multimeter
to a known good ground and note reading
on multimeter.
(4) If continuity is not present in step (3),
repair wire 143 from connector P115-17 to
terminal board 2 pin 27 (para 2-45) or
replace WTEC III dashboard cable
assembly (para 7-11).
(5) Connect positive (+) probe of multimeter
to connector P115 socket 25.
(6) Connect negative (-) probe of multimeter
to a known good ground and note reading
on multimeter.
(7) If continuity is not present in step (6),
repair wire 144 from connector P115-25 to
chassis ground (para 2-45) or replace
WTEC III dashboard cable assembly
(para 7-11).
(8) Connect positive (+) probe of multimeter
to connector P115 socket 32.
(9) Connect negative (-) probe of multimeter
to a known good ground and note reading
on multimeter.
(10) If continuity is not present in step (9),
repair wire 143 from connector P115-32 to
terminal board 2 pin 16 (para 2-45) or
replace WTEC III dashboard cable
assembly (para 7-11).
(11) Connect connector P115 to WTEC III
Transmission ECU.
(12) Connect connector clamp on connector
P115.