TM 9-2320-366-20-2
VOLTAGE TEST
(1) Remove instrument panel assembly for
access (para 7-15).
(2) Start engine (TM 9-2320-366-10-1).
(3) Set multimeter to volts DC.
(4) Disconnect connector J115 (top
connector) from WTEC II TEPSS.
(5) Connect positive (+) probe of multimeter
to connector J115-2.
(6) Connect negative (-) probe of multimeter
to ground and note reading on multimeter.
(7) Connect positive (+) probe of multimeter
to connector J115-11.
(8) Connect negative (-) probe of multimeter
to ground and note reading on multimeter.
(9) If 12 to 14.5 VDC is not present at connector
J115-2 and J115-11, replace WTEC II
cab transmission harness (para 7-137).
(10) Shut down engine (TM 9-2320-366-10-1).