TM 9-2320-366-20-2
CONTINUITY TEST
(1) Disconnect connector P119 from connector
J119.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter to
connector P119R.
(4) Connect negative (-) probe of multimeter to
connector P73 pin C and note reading on
multimeter.
(5) Connect positive (+) probe of multimeter
to connector P119f.
(6) Connect negative (-) probe of multimeter to
connector P73 pin B and note reading on
multimeter.
(7) Connect positive (+) probe of multimeter
to connector P119Z.
(8) Connect negative (-) probe of multimeter to
connector P73 pin A and note reading on
multimeter.
(9) If continuity is not present on one or more
wires, notify DS Maintenance.
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector P119R.
(3) Connect negative (-) probe of multimeter to
all other pins in connector P119, one at a
time, and note reading on multimeter.
(4) If continuity is found between pin R and
any other pin, notify DS Maintenance.
(5) Perform steps (2) and (3) for P119f and
P119Z.
(6) If continuity is found between pin f and
any other pin, or between pin Z and any
other pin, notify DS Maintenance.
(7) Connect connector P73 to TPS connector.