CONTINUITY TEST
(1) Remove two screws and washers from
front grille.
(2) Remove screw and washer from front
grille.
(3) Remove front grille from cab.
(4) Disconnect connector P119 from connector
J119.
(5 Set multimeter to ohms.
(6) Connect positive (+) probe of multimeter
to connector P119n.
(7) Connect negative (-) probe of multimeter to
connector P119g and note reading on
multimeter.
(8) Connect negative (-) probe of multimeter to
all other pins in connector P119, one at a
time, and note reading on multimeter.
(9) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(10) Connect positive (+) probe of multimeter to
connector P119g.
(11) Connect negative (-) probe of multimeter to
all other pins in connector P119 (except
P119n), one at a time, and note reading on
multimeter.
(12) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(13) If continuity 200-400 ohms resistance is not
present in step 7, or continuity is present in
step 8, 9, 11, or 12, notify DS Maintenance.