TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Remove PDP cover (para 16-2).
(2)
Remove relay K12 from PDP.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter to
relay K12 socket 85.
(5)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(6)
If continuity is not present, repair wire 3067
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
relay K12 pin 85.
(3)
Connect negative (-) probe of multimeter to
relay K12 pin 86 and note reading on
multimeter.
(4)
If continuity is not present, replace relay K12
(para 7-9).
2-1573
|