TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Set multimeter to volts dc.
(2)
Connect positive (+) probe of multimeter to
connector P209A or P209B pin 2.
(3)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4)
If continuity is not present, repair wire 3013
(para 2-45) or replace PTO cable
assembly (para 7-127).
(5)
If continuity is present, replace transmission
auxiliary oil cooler fan (para 8-20).
(6)
Connect connector P209A or P209B to
transmission auxiliary oil cooler fan connector.
(7)
Connect connector clamp to connector J209.
(8)
Install circuit breaker CB22 in PDP.
(9)
Install PDP cover (para 16-2).
2-1531
|