TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Disconnect connector P209B from connector
J209B.
(2)
Disconnect connector J209 from transmission
auxiliary oil cooler fan connector.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter to
connector P209B-1.
(5)
Connect negative (-) probe of multimeter to
connector J209-1 and note reading on
multimeter.
(6)
If continuity is not present, repair wire 1811
(para 2-45) or replace oil cooler fan cable
assembly (para 7-136).
(7)
If continuity is present, repair wire 1811
(para 2-45) or replace PTO cable assembly
(para 7-127).
(8)
Connect connector J209 to transmission
auxiliary oil cooler fan connector.
(9)
Connect connector P209B to connector J209B.
CONTINUITY TEST
(1)
Disconnect connector P209B from connector
J209B.
(2)
Disconnect connector J209 from transmission
auxiliary fan connector.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter to
connector P209B-2.
(5)
Connect negative (-) probe of multimeter to
connector J209-2 and note reading on
multimeter.
(6)
If continuity is not present, repair wire 3013
(para 2-45) or replace oil cooler fan cable
assembly (para 7-136).
(7)
If continuity is present, repair wire 3013
(para 2-45) or replace PTO cable assembly
(para 7-127).
(8)
Connect connector J209 to transmission
auxiliary oil cooler fan connector.
(9)
Connect connector P209B to connector J209B.
2-1519
|