TM 9-2320-366-20-2
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
VOLTAGE TEST
(1)
Connect connector L9 to solenoid valve.
(2)
Tighten screw in connector L9.
(3)
Remove six screws from auxiliary panel.
(4)
Lift auxiliary panel outward to gain access.
(5)
Remove PDP cover from PDP (para 16-2).
(6)
Remove circuit breaker CB50 from PDP.
(7)
Disconnect connector P911 from DUMP
BED UP/DOWN switch connector.
(8)
Set multimeter to volts DC.
(9)
Connect positive (+) probe of multimeter
to P911 socket 3.
(10)
Connect negative (-) probe of multimeter
to ground.
(11)
Install circuit breaker CB50 in PDP and
note reading on multimeter.
(12)
If 24 VDC is not present, go to step 9 of
this fault.
(13)
Remove circuit breaker CB50 from PDP.
Change 1
2-1499
|