TM 9-2320-366-20-2
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to connector L8 socket 1.
(3) Connect negative (-) probe of multimeter
to ground and note reading on
multimeter.
(4) If continuity is not present, go to step 4
of this fault.
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to terminal 1 on up solenoid.
(3) Connect negative (-) probe of multimeter to
terminal 2 on up solenoid and note
reading on multimeter.
(4) If continuity is not present, replace
solenoid valve (para 7-142).
(5) If continuity is present, notify DS
Maintenance to perform Dump Body
Hydraulic System troubleshooting task
k1. Dump Body Does Not Raise.
(6) Connect connector L8 to solenoid
valve.
(7) Tighten screw in connector L8.
Change 2