TM 9-2320-366-20-2
CONTINUITY TEST
(1) Remove circuit breaker CB50 from PDP.
(2) Remove electrical tape from conductor
splice at pneumatic solenoid L19.
(3) Cut wire 19 from conductor splice at
pneumatic solenoid L19.
(4) Set multimeter to ohms.
(5) Connect positive (+) probe of multimeter
to terminal block TB19.
(6) Connect negative (-) probe of multimeter to
wire 19 and note reading on multimeter.
(7) If continuity is not present, replace M1089
winch control wiring harness (para 7-142).
Change 1
2-1456.21
|