|
|
TM 9-2320-366-20-2
CONTINUITY TEST
(1) Remove circuit breaker CB50 from PDP.
(2) Remove electrical tape from conductor
splice at pneumatic solenoid L17.
(3) Cut wire 18 from conductor splice at
pneumatic solenoid L17.
(4) Set multimeter to ohms.
(5) Connect positive (+) probe of multimeter
to terminal block TB18.
(6) Connect negative (-) probe of multimeter to
wire 18 and note reading on multimeter.
(7) If continuity is not present, replace M1089
winch control wiring harness (para 7-142).
Change 1
2-1456.17
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |