TM 9-2320-366-20-2
CONTINUITY TEST
(1)
Remove PDP cover (para 16-2).
(2)
Remove circuit breaker CB50 from PDP.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter
to terminal block TBC(1).
(5) Connect negative (-) probe of multimeter to
to terminal block TBC(2) and note reading
on multimeter.
(6) Connect positive (+) probe of multimeter
to terminal block TBC(2).
(7) Connect negative (-) probe of multimeter to
to terminal block TBC(3) and note reading
on multimeter.
(8) Connect positive (+) probe of multimeter
to terminal block TBC(3).
(9) Connect negative (-) probe of multimeter to
to terminal block TBC(4) and note reading
on multimeter.
(10) Connect positive (+) probe of multimeter
to terminal block TBC(4).
(11) Connect negative (-) probe of multimeter to
to terminal block TBC(5) and note reading
on multimeter.
(12) If continuity is not present between two
terminal blocks noted above, replace
jumper wire between terminal blocks that
continuity is not present (para 7-33).
(13) If continuity is present, perform Wrecker Air
System Troubleshooting task aa4. M1089 LH
And RH 30K Winch FREESPOOL Do Not
Operate.
(14) Install circuit breaker CB50 in PDP.
(15) Install PDP cover (para 16-2).
(16) Install wrecker control panel top cover
(para 14-4).
Change 1
2-1456.15
|