TM 9-2320-366-20-2
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
(1) Remove personnel heater for access
(para 18-9).
(2) Disconnect connector P912 from connector
J912.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter
to connector J108 pin 16.
(5) Connect negative (-) probe of multimeter to
connector J912 pin/socket 1 and note
reading on multimeter.
(6) If continuity is not present, repair wire
2006 from connector J108 pin 16 to
connector J912 socket 1 (para 2-45) or
replace auxiliary panel cable assembly
(para 7-58).
(7) If continuity is present, repair wire 2006
from circuit breaker CB50 socket 2 to
connector P912 pin 1 (para 2-45) or
replace WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(8) Connect connector P912 to connector
J912.
(9) Install personnel heater (para 18-9).
(10) Connect connector J108 to connector
P108.
(11) Install circuit breaker CB50 in PDP.
(12) Install kick panel (para 16-3).
(13) Install wrecker control panel top cover
(para 14-4).
(14) Connect batteries (para 7-57).
Change 1
2-1451
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |