|
|
TM 9-2320-366-20-2
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to terminal block TBC(1).
(3) Connect negative (-) probe of multimeter to
to terminal block TBC(2) and note reading
on multimeter.
(4) Connect positive (+) probe of multimeter
to terminal block TBC(2).
(5) Connect negative (-) probe of multimeter to
to terminal block TBC(3) and note reading
on multimeter.
(6) Connect positive (+) probe of multimeter
to terminal block TBC(3).
(7) Connect negative (-) probe of multimeter to
to terminal block TBC(4) and note reading
on multimeter.
(8) Connect positive (+) probe of multimeter
to terminal block TBC(4).
(9) Connect negative (-) probe of multimeter to
to terminal block TBC(5) and note reading
on multimeter.
(10) If continuity is not present between two
terminal blocks noted above, replace
jumper wire between terminal blocks that
continuity is not present (para 7-33).
(11) If continuity is present, replace M1089
winch control wiring harness (para 7-142).
(12) Close LH and RH catwalks.
(13) Install circuit breaker CB50 in PDP.
(14) Install wrecker control panel top cover
(para 14-4).
Change 1
2-1450.11
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |