WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuit
and cause severe burns or electrical shock.
VOLTAGE TEST
(1)
Set multimeter to vdc.
(2)
Position station selector switch to REMOTE
CONTROL (TM 9-2320-366-10-1).
(3)
Connect positive (+) probe of multimeter to
pin C of connector J1 and/or J2.
(4)
Connect negative (-) probe of multimeter to
ground.
(5)
Position master power switch to on
(TM 9-2320-366-10-1) and note reading on
multimeter.
(5)
If 24 vdc is not present, repair wire 7 (para
2-45), or replace wrecker control panel
wiring harness (para 7-83).
(6)
If 24 vdc is present, perform Wrecker
Pneumatic Troubleshooting (aa1. All Wrecker
Functions Do Not Operate From Wrecker
Remote Control).
(7)
Position master power switch to off
(TM 9-2320-366-10-1).