Page Title: CONTINUITY TEST
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector J4-a.
(3)
Connect negative (-) probe of multimeter to
wrecker control panel terminal board position
C and note reading on multimeter.
(4)
Connect positive (+) probe of multimeter to
connector J4-b.
(5)
Connect negative (-) probe of multimeter to
wrecker control panel terminal board position
C and note reading on multimeter.
(6)
If continuity is not present at connector J4-a
and/or J4-b, repair wire 9 (para 2-45) or
replace wrecker control panel wiring harness
(para 7-83).
(7)
If continuity is present, repair wire 3087
(para 2-45) or replace rear lights cable
assembly (para 7-104).
(8)
Connect connector P107 to connector J4.
(9)
Install top control panel cover (para 17-20).