CONTINUITY TEST
(1)
Loosen four screws on junction box.
(2)
Open cover on junction box.
(3)
Disconnect telescope out lockout solenoid
cable connector from telescope out
lockout solenoid valve.
(4)
Set multimeter to ohms.
(5)
Connect positive (+) probe of multimeter in
socket 1 of telescope out lockout solenoid
cable.
(6)
Connect negative (-) probe of multimeter to
terminal board position 19 and note reading on
multimeter.
(7)
If continuity is not present, replace telescope
out lockout solenoid cable (para 7-122).
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter in
socket 2 of telescope out lockout solenoid
cable connector.
(3)
Connect negative (-) probe of multimeter on
ground in junction box and note reading
on multimeter.
(4)
If continuity is not present, replace telescope
out lockout solenoid cable (para 7-122).
(5)
Connect telescope out lockout solenoid cable
connector to telescope out lockout solenoid
valve.
(6)
Close cover on junction box.
(7)
Tighten four screws on junction box cover.