TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Loosen four screws on junction box.
(2)
Open cover on junction box.
(3)
Disconnect boom up lockout solenoid cable
connector from boom up lockout solenoid
valve.
(4)
Set multimeter to ohms.
(5)
Connect positive (+) probe of multimeter in
socket 1 of boom up lockout solenoid cable.
(6)
Connect negative (-) probe of multimeter to
terminal board position 19 and note reading
on multimeter.
(7)
If continuity is not present, replace boom up
lockout solenoid cable (para 7-107).
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter in
socket 2 of boom up lockout solenoid cable
connector.
(3)
Connect negative (-) probe of multimeter on
ground in junction box and note reading
on multimeter.
(4)
If continuity is not present, replace boom up
lockout solenoid cable (para 7-107).
(5)
Connect boom up lockout solenoid cable
connector to boom up lockout solenoid valve.
(6)
Close cover on junction box.
(7)
Tighten four screws on junction box cover.