TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Disconnect boom down solenoid connector from
boom down solenoid.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter on pin
2 of boom down solenoid cable connector.
(4)
Connect negative (-) probe of multimeter on
ground and note reading on multimeter.
(5)
Connect positive (+) probe of multimeter on pin
1 of boom down solenoid cable connector.
(6)
Connect negative (-) probe of multimeter on
terminal board lower position 14 and note
reading on multimeter.
(7)
If continuity is not present, replace boom down
solenoid cable (para 7-106).
(8)
If continuity is present, notify DS Maintenance.
(9)
Connect boom down solenoid cable connector to
boom down solenoid.
(10)
Close cover on junction box.
(11)
Tighten four screws on junction box cover.
(12)
Stow crane (TM 9-2320-366-10-1).
2-1345
|