TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Disconnect hoist down solenoid connector from
hoist down solenoid.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter on pin
2 of hoist down solenoid cable connector.
(4)
Connect negative (-) probe of multimeter on
ground and note reading on multimeter.
(5)
Connect positive (+) probe of multimeter on pin
1 of hoist down solenoid cable connector.
(6)
Connect negative (-) probe of multimeter on
terminal board lower position 24 and note
reading on multimeter.
(7)
If continuity is not present, replace hoist down
solenoid cable (para 7-111).
(8)
If continuity is present, notify DS Maintenance.
(9)
Connect hoist down solenoid cable connector to
hoist down solenoid.
(10)
Close cover on junction box.
(11)
Tighten four screws on junction box cover.
(12)
Stow crane (TM 9-2320-366-10-1).
2-1321
|