CONTINUITY TEST
(1)
Disconnect telescope out solenoid connector
from telescope out solenoid.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter on pin
2 of telescope out solenoid cable connector.
(4)
Connect negative (-) probe of multimeter on
ground and note reading on multimeter.
(5)
Connect positive (+) probe of multimeter on pin
1 of telescope out solenoid cable connector.
(6)
Connect negative (-) probe of multimeter on
terminal board lower position 19 and note
reading on multimeter.
(7)
If continuity is not present, replace telescope
out solenoid cable (para 7-103).
(8)
If continuity is present, notify DS Maintenance.
(9)
Connect telescope out solenoid cable connector
to telescope out solenoid.
(10)
Close cover on junction box.
(11)
Tighten four screws on junction box cover.
(12)
Stow crane (TM 9-2320-366-10-1).
2-1239
|