TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Disconnect telescope in solenoid connector from
telescope in solenoid.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter on pin
2 of telescope in solenoid cable connector.
(4)
Connect negative (-) probe of multimeter on
ground and note reading on multimeter.
(5)
Connect positive (+) probe of multimeter on pin
1 of telescope in solenoid cable connector.
(6)
Connect negative (-) probe of multimeter on
terminal board lower position 20 and note
reading on multimeter.
(7)
If continuity is not present, replace telescope in
solenoid cable (para 7-101).
(8)
If continuity is present, notify DS Maintenance.
(9)
Connect telescope in solenoid cable connector to
telescope in solenoid.
(10)
Close cover on junction box.
(11)
Tighten four screws on junction box cover.
(12)
Stow crane (TM 9-2320-366-10-1).