TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Disconnect boom up solenoid connector from
boom up solenoid.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter on pin
2 of boom up solenoid cable connector.
(4)
Connect negative (-) probe of multimeter on
ground and note reading on multimeter.
(5)
Connect positive (+) probe of multimeter on pin
1 of boom up solenoid cable connector.
(6)
Connect negative (-) probe of multimeter on
terminal board lower position 21 and note
reading on multimeter.
(7)
If continuity is not present, replace boom up
solenoid cable (para 7-88).
(8)
If continuity is present, notify DS Maintenance.
(9)
Connect boom up solenoid cable connector to
boom up solenoid.
(10)
Close cover on junction box.
(11)
Tighten four screws on junction box cover.
(12)
Stow crane (TM 9-2320-366-10-1).
2-1203
|