TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Disconnect hoist up solenoid connector from
hoist up solenoid.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter on pin
2 of hoist up solenoid cable connector.
(4)
Connect negative (-) probe of multimeter on
ground and note reading on multimeter.
(5)
Connect positive (+) probe of multimeter on pin
1 of hoist up solenoid cable connector.
(6)
Connect negative (-) probe of multimeter on
terminal board lower position 23 and note
reading on multimeter.
(7)
If continuity is not present, replace hoist up
solenoid cable (para 7-93).
(8)
If continuity is present, notify DS Maintenance.
(9)
Connect hoist up solenoid cable connector to
hoist up solenoid.
(10)
Close cover on junction box.
(11)
Tighten four screws on junction box cover.
(12)
Stow crane (TM 9-2320-366-10-1).
2-1179
|