TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Position ON/OFF switch to ON.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter on pin
H of remote control box receptacle.
(4)
Connect negative (-) probe of multimeter on pin
J of remote control box receptacle and note
reading on multimeter.
(5)
If continuity is not present, replace ON/OFF
switch (para 7-32).
(6)
Position ON/OFF switch to OFF.
(7)
Connect positive (+) probe of multimeter on pin
E of remote control box recptacle.
(8)
Connect negative (-) probe of multimeter on pin
K of remote control box receptacle and note
reading on multimeter.
(9)
If continuity is not present, replace ON/OFF
switch (para 7-32).
(10)
If continuity is present, notify DS Maintenance.
2-1175
|