e101. AIR DRYER DOES NOT OPERATE (ALL MODELS EXCEPT M1090/M1094) (CONT)
e101.
WARNING
Read WARNING
KNOWN INFO
TEST OPTIONS
3.
on following page.
Air hoses and fittings OK.
Voltage Test or
Air compressor
STE/ICE-R #89
Is 24 vdc present on
governor OK.
REASON FOR QUESTION
connector J43-9?
Air dryer OK.
If 24 vdc is not present,
wire 1481 in dashboard
POSSIBLE PROBLEMS
cable assembly is faulty.
Faulty dashboard
If 24 vdc is present,
cable assembly.
wire 1481 in start and
Faulty start and charging
NO
charging cable assembly
cable assembly.
is faulty.
YES
Repair wire 1481 (para 2-45)
or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
Repair wire 1481 (para 2-45)
or replace start and charging
cable assembly (para 7-132).