TM 9-2320-366-20-2
TM
WARNING
Remove rings, bracelets, watches,
necklaces, and any other jewelry
before working around vehicle.
Jewelry can catch on equipment
and cause injury or short across
electrical circuit and cause severe
burns or electrical shock.
VOLTAGE TEST
(1)
Disconnect connector clamp from ether valve
connector.
(2)
Disconnect ether valve connector
from connector J93.
(3)
Disconnect connector clamp from ether sensor
connector.
(4)
Disconnect connector P42 from ether sensor
connector.
(5)
Install jumper wire from connector P42-1 to
connector P42-2.
(6)
Set multimeter to volts dc.
(7)
Connect positive (+) probe of multimeter to
connector J93-1.
(8)
Connect negative (-) probe of multimeter to
ground.
(9)
Position master power switch to on
(TM 9-2320-366-10-1).
(10)
Press ether start switch (TM 9-2320-366-10-1)
and note reading on multimeter.
(11)
If 24 vdc is not present, go to step 3 of this
fault.
(12)
Release ether start switch
(TM 9-2320-366-10-1).
(13)
Position master power switch to off
(TM 9-2320-366-10-1).
(14)
Remove jumper wire from connector P42-1 and
connector P42-2.
(15)
Connect connector P42 to ether sensor
connector.
(16)
Lower cab (TM 9-2320-366-10-1).
2-1111
|