e95. ENGINE FAN RUNS CONSTANTLY (CONT)
e95.
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING
2.
Engine fan turns off using
Voltage Test or
on following page.
deep water fording switch.
STE/ICE-R #89
Is 24 vdc present at
REASON FOR QUESTION
Water temperature switch
connector P36-2?
This question eliminates
OK.
POSSIBLE PROBLEMS
possible problems and
Faulty dashboard cable
determines where
assembly.
troubleshooting continues.
NO
Faulty engine control cable
assembly.
YES
Go to step 4 of this fault.
KNOWN INFO
TEST OPTIONS
3.
Engine fan turns off using
Continuity Test or
deep water fording switch.
STE/ICE-R #91
Is continuity present
REASON FOR QUESTION
Water temperature switch
between connector P36-1?
This question eliminates
OK.
POSSIBLE PROBLEMS
possible problems and
Faulty dashboard cable
determines where
assembly.
troubleshooting continues.
NO
Faulty engine control cable
assembly.
YES
Go to step 5 of this fault.
Fault corrected.