TM 9-2320-366-20-2
TM
WARNING
Remove rings, bracelets, watches,
necklaces, and any other jewelry
before working around vehicle.
Jewelry can catch on equipment
and cause injury or short across
electrical circuit and cause severe
burns or electrical shock.
VOLTAGE TEST
(1)
Remove WTEC III relay K34 from PDP.
(2)
Set multimeter to volts dc.
(3)
Connect positive (+) probe of multimeter to
PDP, terminal 30, where WTEC III relay K34
was removed.
(4)
Connect negative (-) probe of multimeter
to ground.
(5)
Position master power switch to on
(TM 9-2320-366-10-1) and note reading on
multimeter.
(6)
If 24 vdc is not present, repair wire 1692
(para 2-45) or replace WTEC III dashboard
cable assembly (para 7-11).
(7)
Position master power switch to off
(TM 9-2320-366-10-1).
2-1083
|