|
|
TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Loosen screw and disconnect connector
PX33 from WTEC II VIM.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter to
WTEC II VIM connector J116C3.
(4)
Connect negative (-) probe of multimeter to
WTEC II VIM connector terminal J3 and note
reading on multimeter.
(5)
If continuity is not present, replace WTEC II
VIM (para 8-6).
(6)
Connect connector J116 to WTEC II VIM.
(7)
Connect connector PX33 to WTEC II VIM and
tighten screw.
2-1061
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |