TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Loosen screw in connector PX33.
(2)
Disconnect connector PX33 from WTEC II VIM.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter to
connector J913-15.
(5)
Connect negative (-) probe of multimeter to
connector PX33-E3 and note reading on
multimeter.
(6)
If continuity is not present, repair wire 1904
(para 2-45) or replace WTEC II dashboard cable
assembly (para 7-10).
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector PX33-E2.
(3)
Connect negative (-) probe of multimeter to
connector J913-14 and note reading on
multimeter.
(4)
If continuity is not present, repair wire 2019
(para 2-45) or replace WTEC II dashboard cable
assembly (para 7-10).
(5)
Connect connector PX33 to WTEC II VIM.
(6)
Tighten screw in connector PX33.
2-1029
|