e89. 15K SELF-RECOVERY WINCH (SRW) DOES NOT REEL IN (CONT)
e89.
KNOWN INFO
TEST OPTIONS
6.
Circuit breaker OK.
Continuity Test or
15K SRW pays out.
STE/ICE-R #91
Is continuity present
Winch control valve
between connector
REASON FOR QUESTION
assembly OK.
If continuity is not present,
J215-2 and winch in
WINCH IN/OUT switch OK.
wire 2005 is faulty. If
solenoid L4 connector
Auxiliary panel cable
continuity is present, notify
terminal 1?
assembly OK.
DS Maintenance.
PTO cable assembly OK.
POSSIBLE PROBLEMS
NO
Faulty winch control valve
cable assembly.
Repair wire 2005 (para 2-45)
or replace winch control valve
YES
cable assembly (para 7-135).
Notify DS Maintenance.