TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector P110-R.
(3)
Connect negative (-) probe of multimeter to
connector P112-D and note reading on
multimeter.
(4)
If continuity is not present, replace CTIS cable
assembly (para 7-60).
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector P110-F.
(3)
Connect negative (-) probe of multimeter to
connector P112-B and note reading on
multimeter.
(4)
If continuity is not present, replace CTIS cable
assembly (para 7-60).
(5)
Connect connector P112 to manifold valve
assembly.
2-975
|