|
|
TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Remove kick panel (para 16-3).
(2)
Disconnect connector P112 from manifold
valve assembly.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter to
connector P110-C.
(5)
Connect negative (-) probe of multimeter to
connector P112-E and note reading on
multimeter.
(6)
If continuity is not present, replace CTIS cable
assembly (para 7-60).
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector P110-F.
(3)
Connect negative (-) probe of multimeter to
connector P112-A and note reading on
multimeter.
(4)
If continuity is not present, replace CTIS
cable assembly (para 7-60).
2-973
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |