TM 9-2320-366-20-2
CONTINUITY TEST
(1) Remove kick panel (para 16-3).
(2) Disconnect connector P112 from pneumatic
controller connector.
(3) Disconnect connector J111 from connector
P111.
(4) Set multimeter to ohms.
(5) Connect positive (+) probe of multimeter to
connector P111 pin A.
(6) Connect negative (-) probe of multimeter to
connector P112 socket A and note reading
on multimeter.
(7) If continuity is not present, replace CTIS
cable assembly (para 7-60).
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector P111 pin A.
(3) Connect negative (-) probe of multimeter to
connector P112 socket B and note reading
on multimeter.
(4) If continuity is not present, replace CTIS
cable assembly (para 7-60).
(5) Connect connector J111 from connector
P111.