TM 9-2320-366-20-1
TM
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
PDP, terminal 85, where relay K32 was
removed.
(3)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4)
If continuity is not present, repair wire 3036
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuit
and cause severe burns or electrical shock.
VOLTAGE TEST
(1) Set multimeter to volts dc.
(2) Connect positive (+) probe of multimeter to
PDP, terminal 30, where relay K32 was
removed.
(3) Connect negative (-) probe of multimeter to
ground.
(4) Position master power switch to on
(TM 9-2320-366-10-1) and note reading on
multimeter.
(5) If 24 vdc is not present, repair wire 26
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(6) Position master power switch to off
(TM 9-2320-366-10-1).