TM 9-2320-366-20-1
TM
WARNING
Remove rings, bracelets, watches,
necklaces, and any other jewelry
before working around vehicle.
Jewelry can catch on equipment
and cause injury or short across
electrical circuit and cause severe
burns or electrical shock.
VOLTAGE TEST
(1)
Remove heater fan control switch
(para 18-10).
(2)
Set multimeter to volts dc.
(3)
Connect positive (+) probe of multimeter to
personnel heater fan control switch blue wire.
(4)
Connect negative (-) probe of multimeter to
ground.
(5)
Position master power switch to on
(TM 9-2320-366-10-1) and note reading on
multimeter.
(6)
If 24 vdc is not present, go to step 5 of
this fault.
(7)
Position master power switch to off
(TM 9-2320-366-10-1).
2-869
|