TM 9-2320-366-20-1
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
(1)
Remove PDP cover (para 16-2).
(2)
Remove relay K27 from PDP.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter
to connector J130 socket F.
(5) Connect negative (-) probe of multimeter
to relay K27 terminal 87 on PDP and note
reading on multimeter.
(6) If continuity is not present, go to step 6
of this fault.
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
VOLTAGE TEST
(1) Set multimeter to volts DC.
(2) Connect positive (+) probe of multimeter
to relay K27 terminal 30 on PDP.
(3) Connect negative (-) probe of multimeter
to ground.
(4) Position main light switch to BO DRIVE
(TM 9-2320-366-10-1) and note reading
on multimeter.
(5) If 24 VDC is not present, repair wire 1959
from K27 terminal 30 on PDP to circuit
breaker CB39 terminal 4 (para 2-45) or
replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(6) Position main light switch to OFF
(TM 9-2320-366-10-1).
Change 1
2-829
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |