TM 9-2320-366-20-1
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
terminal lug TL502.
(3) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4) If continuity is not present, repair wire 3042
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(5) If contintuity is present, replace M1088
trailer stoplight switch (para 11-34).
(6) Install kick panel (para 16-3).