TM 9-2320-366-20-1
TM
WARNING
Remove rings, bracelets, watches,
necklaces, and any other jewelry
before working around vehicle.
Jewelry can catch on equipment
and cause injury or short across
electrical circuit and cause severe
burns or electrical shock.
VOLTAGE TEST
(1)
Remove circuit breaker CB76 from PDP.
(2)
Set multimeter to volts dc.
(3)
Connect positive (+) probe of multimeter to
PDP, terminal 3, where circuit breaker CB76
was removed.
(4)
Connect negative (-) probe of multimeter to
ground.
(5)
Position master power switch to on
(TM 9-2320-366-10-1) and note reading on
multimeter.
(6)
If 12 vdc is not present, repair wire 1548
(para 2-45) or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III dashboard
cable assembly (para 7-11).
(7)
If 12 vdc is present, repair wire 1641
(para 2-45) or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III dashboard
cable assembly (para 7-11).
(8)
Position master power switch to off
(TM 9-2320-366-10-1).
(9)
Install circuit breaker CB76 in PDP.
(10)
Install relay K6 in PDP.
(11)
Install PDP cover (para 16-2).
2-781
|