TM 9-2320-366-20-1
e48A. ALL MARKER LIGHTS DO NOT ILLUMINATE IN NORMAL MODE (CONT)
KNOWN INFO
TEST OPTIONS
5.
Continuity Test or
Circuit breaker CB67 OK.
STE/ICE-R Test #91
No marker lights illuminate.
Is continuity present from
Main light switch OK.
REASON FOR QUESTION
relay K20 terminal 85 on
POSSIBLE PROBLEMS
If continuity is not present,
PDP to ground?
wire 3054 is faulty.
Faulty dashboard cable
assembly.
Faulty relay K20.
NO
Repair wire 3054 from relay K20
terminal 85 on PDP to terminal board
TB2 position 44 on PDP (para 2-45) or
YES
replace WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
Replace relay K20
(para 7-9).
2-604.64
Change 1
|