CONTINUITY TEST
(1)
Remove PDP cover (para 16-2).
(2)
Remove relay K8 from PDP.
(3)
Disconnect connector P12 (RH) or connector
P4 (LH) from housing.
(4)
Set multimeter to ohms.
(5)
Connect positive (+) probe of multimeter to
connector P12 (RH) or connector P4 (LH).
(6)
Connect negative (-) probe of multimeter to
PDP, terminal 87A, where relay K8 was
removed and note reading on multimeter.
(7)
If continuity is not present, go to step 5
of this fault.
(8)
Connect connector P12 (RH) or connector
P5 (LH) to housing.
CONTINUITY TEST
(1)
Set multimeter to ohms
(2)
Connect positive (+) probe of multimeter to
relay K8 terminal 87A.
(3)
Connect negative (-) probe of multimeter to
relay K8 terminal 30 and note reading on
multimeter.
(4)
If continuity is not present, replace relay K8
(para 7-9).
(5)
If continuity is present, replace turn signal
switch (para 7-26).
(6)
Install relay K8 in PDP.
(7)
Install PDP cover (para 16-2).