TM 9-2320-366-20-1
TM
CONTINUITY TEST
(1)
Remove PDP cover (para 16-2).
(2)
Remove relay K11 from PDP.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter to
PDP, terminal 85, where relay K11 was
removed.
(5)
Connect negative (-) probe of multimeter to
PX7-23 and note reading on multimeter.
(6)
If continuity is not present, repair wire 34A
(para 2-45) or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III dashboard
cable assembly (para 7-11).
(7)
Install relay K11 in PDP.
(8)
Install PDP cover (para 16-2).
(9)
Connect lighted indicator display to connector
PX7.
(10)
Position lighted indicator display in instrument
panel assembly with four screws.
(11)
Tighten four screws to 6-10 lb-in. (1 Nm).
(12)
Connect batteries (para 7-57).