CONTINUITY TEST
(1)
Loosen four captive screws in lamp mounting
panel.
(2)
Remove lamp mounting panel from lighted
indicator display housing.
(3)
Remove dump up indicator lamps from
printed circuit board.
(4)
Set multimeter to ohms.
(5)
Check continuity through each dump up
indicator lamp and note reading on
(6)
If continuity is not present, replace dump up
indicator lamps (para 7-16).
(7)
If continuity is present, replace lighted
indicator display (para 7-16).
(8)
Install dump up indicator lamps in printed
circuit board.
(9)
Install lamp mounting panel in lighted
indicator display housing.
(10)
Tighten four captive screws in lamp mounting
panel.
(11)
Connect lighted indicator display to connector
PX7.
(12)
Position lighted indicator display in instrument
panel assembly with four screws.
(13)
Tighten four screws to 6-10 lb-in. (1 Nm).
(14)
Connect batteries (para 7-57).