(1)
Remove personnel heater for access (para 18-9).
(2)
Disconnect connector P913 from connector
J913.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter to
PX7-10.
(5)
Connect negative (-) probe of multimeter to
J913-13 and note reading on multimeter.
(6)
If continuity is not present, repair wire 2021
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(7)
Connect lighted indicator display to connector
PX7.
(8)
Position lighted indicator display in instrument
panel assembly with four screws.
(9)
Tighten four screws to 6-10 lb-in. (1 Nm).
(10)
Connect batteries (para 7-57).