CONTINUITY TEST
(1) Loosen four captive screws in lamp
mounting panel.
(2) Remove lamp mounting panel from lighted
indicator display housing.
(3) Remove emergency brake indicator lamps
from printed circuit board.
(4) Set multimeter to ohms.
(5) Check continuity through each emergency
brake indicator lamp and note reading on
(6) If continuity is not present in both lamps,
replace lamps (para 7-16).
(7) If continuity is present in either lamp,
replace lighted indicator display
(para 7-16).
(8) Install emergency brake indicator lamps in
printed circuit board.
(9) Install lamp mounting panel in lighted
indicator display housing.
(10) Tighten four captive screws in lamp
mounting panel.
(11) Connect lighted indicator display to
connector PX7.
(12) Position lighted indicator display in
instrument panel assembly with four
screws.
(13) Tighten four screws to 6-10 lb-in. (1 Nm).
(14) Connect batteries (para 7-57).
Change 1