TM 9-2320-366-20-1
TM
CONTINUITY TEST
(1)
Remove four screws from lighted indicator
display.
(2)
Remove lighted indicator display from
instrument panel assembly.
(3)
Disconnect connector PX7 from lighted
indicator display.
(4)
Set multimeter to ohms.
(5)
Connect positive (+) probe of multimeter to
connector PX7-7.
(6)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(7)
If continuity is not present, repair wire 3021
(para 2-45) or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III dashboard
cable assembly (para 7-11).
(8)
If continuity is present, replace lighted
indicator display (para 7-16).
(9)
Connect lighted indicator display to connector
PX7.
(10)
Position lighted indicator display in instrument
panel assembly with four screws.
(11)
Tighten four screws to 6-10 lb-in. (1 Nm).
(12)
Connect batteries (para 7-57).
2-449
|