TM 9-2320-366-20-1
TM
CONTINUITY TEST
(1)
Loosen four captive screws in lamp mounting
panel.
(2)
Remove lamp mounting panel from lighted
indicator display housing.
(3)
Remove left turn signal indicator lamps from
printed circuit board.
(4)
Set multimeter to ohms.
(5)
Check continuity through each left turn signal
indicator lamp and note reading on
(6)
If continuity is not present, replace lamps
(para 7-16).
(7)
If continuity is present, replace lighted
indicator display (para 7-16).
(8)
Install left turn signal indicator lamps in
printed circuit board.
(9)
Install lamp mounting panel in lighted
indicator display housing.
(10)
Tighten four captive screws in lamp
mounting panel.
(11)
Disconnect batteries (para 7-57).
(12)
Connect lighted indicator display to connector
PX7.
(13)
Position lighted indicator display in instrument
panel assembly with four screws.
(14)
Tighten four screws to 6-10 lb-in. (1 Nm).