TM 9-2320-366-20-1
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
(1) Position dimmer switch for maximum
brightness (TM 9-2320-366-10-1).
(2) Install dimmer switch test wire pin in
connector PX24 socket 1.
(3) Install dimmer switch test wire socket
on dimmer switch connector pin 1.
(4) Set multimeter to volts DC.
(5) Connect positive (+) probe of multimeter
to dimmer switch connector socket 2.
(6) Connect negative (-) probe of multimeter to
ground.
(7) Position main light switch main selector
lever to SER DRIVE (TM 9-2320-366-10
-1).
(8) Position main light switch auxiliary lever to
PNL BRT (TM 9-2320-366-10-1) and note
reading on multimeter.
(9) If 12 VDC is not present, replace dimmer
switch (para 7-12).
(10) Position main light switch auxiliary lever to
OFF (TM 9-2320-366-10-1).
(11) Position main light switch main selector
lever to OFF (TM 9-2320-366-10-1).
(12) Disconnect dimmer switch test wire from
dimmer switch connector.
(13) Disconnect dimmer switch test wire from
connector PX24.
Change 1
2-394.5
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |