TM 9-2320-366-20-1
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
(1) Remove instrument panel for access (para
7-15).
(2) Disconnect connector P31 from connector
J31.
(3) Raise cab (TM 9-2320-366-10-1).
(4) Disconnect connector clamp from connector
P39.
(5) Disconnect connector P39 from connector
J39.
(6) Set multimeter to ohms.
(7) Connect positive (+) probe of multimeter to
connector P39 socket 2.
(8) Connect negative (-) probe of multimeter to
connector P31 socket 17 and note reading
on multimeter.
(9) If continuity is not present, repair wire 32 in
engine control cable (para 2-45) or replace
engine control cable assembly (para 7-80).
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector P39 pin 1.
(3) Connect negative (-) probe of multimeter to
connector P31 socket 9 and note reading on
multimeter.
(4) If continuity is not present, repair wire 3028
in engine control cable (para 2-45) or
replace engine control cable assembly (para
7-80).